Gas Sample Probes

SP180-H-EX2-T2 Zone 2

02S1890

  • heated to 180°C, for sampling from Ex-zone 2, with ceramic filter element outside, optional: sample tubes and pre-filter or use in Ex-Zone 2 G

Configure Product

he M&C sample probes version SP180EX2 are used for continuous extraction of explosive gases (Ex-zone 2) from dust loaden, high temperature and/or humid processes. The probes can be mounted in Ex-zone 2.

Gas sample probe type SP180-H. Explosion-proof version for mountage in Ex-Zone 2 and sampling from zone 2 with protection class according to ATEX: Ex II 3G ec mc IIC T2 Gc EXAM BVS 16 ATEX H 039. With external ceramic filter type S-2K (75mm). Filter porosity: 2µm. External filter electrically heated up to 180°C with self-regulated heating elements. Low temperature alarm with potential-free status-alarm contact at -50°C below Tsetting. With a new kind of weather protection shield for outside mounting. Power: 110-240V, 50/60Hz, 400W. Mounting flange: DN65PN6 with thread G3/4"i. Material: SS316, ceramic, Viton. Sample outlet: connector for tube 6mm OD. Calibration gas inlet: connector for tube 6mm OD with blind plug.

Close X

Full-span setting for O₂ analysers

Enter the expected altitude of the site. You receive the full span in (Vol.-% O₂), calibration with air at 1013 mbar.

1

  • Result:
  • 22,9378
  • O₂ - span adjustment [Vol.-%]*

*Air with normal pressure 1013 mbar = 20,93 Vol.-% O₂.

Pressure drop and delay time

Please enter your data in fields 1 - 3.

1

2

3

  • Result:
  • 3,39
  • Delay time ca. in [s]*

* single change of gas, for 90%-response time approx. 3 changes of sample volume are required.

Calculation of pressureless 100% H₂O-saturation

Enter a value that you would like calculated. All other fields will show the converted value automatically.
The calculation provides only in the temperature range between -20°C and +90°C sufficiently accurate values.

Pressure units

Enter a value that you would like calculated. All other fields will show the converted value automatically.

Temperature units

Enter a value that you would like calculated. All other fields will show the converted value automatically.

Length units

Enter a value that you would like calculated. All other fields will show the converted value automatically.

Area units

Enter a value that you would like calculated. All other fields will show the converted value automatically.

Volume units

Enter a value that you would like calculated. All other fields will show the converted value automatically.

Weight units

Enter a value that you would like calculated. All other fields will show the converted value automatically.

Energy units

Enter a value that you would like calculated. All other fields will show the converted value automatically.

Flow rate

Enter a value that you would like calculated. All other fields will show the converted value automatically.

Flow speed

Enter a value that you would like calculated. All other fields will show the converted value automatically..

Here you can find more information.

  • Spare parts for SP180-H-EX2-T2 Zone 2
    • Filter element S-2K
      Filter element S-2K Item No.: 90S0015

      Filter element type S-2K. Length: 75mm, material: ceramics, filter porosity: 2µm.

    • Filter element type S-0,1GF, 75mm
      Filter element type S-0,1GF, 75mm Item No.: 90S0017

      Filter element type S-0,1GF. Length: 75mm, material: glass fibre, filter porosity: 0,1µm.

    • Gasket 30         Viton
      Gasket 30 Viton Item No.: 93S0045

      Gasket (30) for filter element. Material: Viton.

    • O-Ring Viton  39,00x3,50
      O-Ring Viton 39,00x3,50 Item No.: 93S0020

      O-ring (39) for SP2000 and CLF. Material: Viton.

    • O-Ring Viton  55,00x3,50
      O-Ring Viton 55,00x3,50 Item No.: 93S0025

      O-ring (55) for SP2000. Material: Viton.

Configure your product:

  • Step 1
  • Step 2
  • Step 3
  • Step 4
1. Step: Choose amount

pcs

Please choose amount!

This is a short description of the green highlighted term.
2. Step: Choose product options
  • Your amount SP180-H-EX2-T2 Zone 2 (02S1890): pcs
  • Your options:

    Options for SP180-H-EX2-T2 Zone 2

    3. Step: Choose parts
    • Your amount SP180-H-EX2-T2 Zone 2 (02S1890): pcs
    • Your options:
      • Your spare parts:

        Spare parts for SP180-H-EX2-T2 Zone 2

        • Filter element S-2K
          Filter element S-2K Item No.: 90S0015

          Filter element type S-2K. Length: 75mm, material: ceramics, filter porosity: 2µm.

          Add
          This is a short description of the green highlighted term.
        • Filter element type S-0,1GF, 75mm
          Filter element type S-0,1GF, 75mm Item No.: 90S0017

          Filter element type S-0,1GF. Length: 75mm, material: glass fibre, filter porosity: 0,1µm.

          Add
          This is a short description of the green highlighted term.
        • Gasket 30         Viton
          Gasket 30 Viton Item No.: 93S0045

          Gasket (30) for filter element. Material: Viton.

          Add
          This is a short description of the green highlighted term.
        • O-Ring Viton  39,00x3,50
          O-Ring Viton 39,00x3,50 Item No.: 93S0020

          O-ring (39) for SP2000 and CLF. Material: Viton.

          Add
          This is a short description of the green highlighted term.
        • O-Ring Viton  55,00x3,50
          O-Ring Viton 55,00x3,50 Item No.: 93S0025

          O-ring (55) for SP2000. Material: Viton.

          Add
          This is a short description of the green highlighted term.
        4. Step: Add to request
        • Your amount SP180-H-EX2-T2 Zone 2 (02S1890): pcs
        • Your options:
          • Your spare parts:
            Item added

            Item added successful.

            Close