Description
Compressor gas cooler type ECM‑Ex2‑1, ATEX certified version for hazardous zone 2 areas with the marking: II 3G Ex nA nC IIC T4 Gc , in wall‑mount enclosure, housing depth: 260 mm, prepared for 1 Jet‑Stream heat exchanger with 250 Nl/h, high and low‑temperature alarm window as well as sample gas outlet dew point adjustable at the integrated electronic controller, factory‑set to +5 °C, with 1 contact output, thermometer with digital display: ‑10/+50 °C, power: 115 V/60 Hz